  • 10-20 system: The international method of placing electrodes at 10% and 20% of measured head distances.
  • ABRET: The board that awards neurodiagnostic credentials such as R. EEG T. and CLTM.
  • ACNS: American Clinical Neurophysiology Society, which publishes EEG guidelines and terminology.
  • Alpha rhythm: 8 to 13 Hz activity, strongest over the back of the head with the eyes closed in a relaxed awake adult.
  • Ambulatory EEG: A portable recorder worn at home, often for 24 to 72 hours.
  • Artifact: Any signal on the EEG that does not come from the brain.
  • ASET: The Neurodiagnostic Society: a professional organization with courses, CEUs and conferences.
  • Beta activity: Faster than 13 Hz. Often increased by sedative medications such as benzodiazepines.
  • Bipolar montage: Each channel compares two neighboring electrodes, linked in chains.
  • Breach rhythm: Sharper, higher activity over a skull defect, because the skull no longer dampens the signal.
  • Burst suppression: Bursts of activity separated by periods of very low voltage. Seen with deep anesthesia or severe injury.
  • Calibration: Sending a known signal through every channel to confirm the amplifiers respond the same way.
  • CLTM: ABRET’s Certification in Long Term Monitoring credential.
  • Collodion: An adhesive that holds electrodes for days. Flammable; needs ventilation and a solvent to remove.
  • Common mode rejection: The amplifier cancelling a signal that reaches both inputs equally, such as room noise.
  • Continuous EEG: Ongoing EEG monitoring, usually in the ICU (cEEG).
  • Delta activity: Slower than 4 Hz. Normal in deep sleep and infants; focal delta in an awake adult draws attention.
  • Differential amplifier: Shows the difference between two inputs, so noise reaching both equally is cancelled.
  • Double banana: Nickname for the longitudinal bipolar montage: front-to-back chains on each side.
  • Encephalopathy: Widespread brain dysfunction, for example from infection, metabolic problems or medications.
  • Epilepsy monitoring unit: A planned admission to capture a patient’s events on video EEG.
  • Epileptiform discharge: Spikes or sharp waves linked with a tendency to have seizures.
  • Focal slowing: Delta or theta in one area. It can point to a local problem under that area.
  • Generalized slowing: Slowing everywhere, often seen with encephalopathy.
  • Ground electrode: Not a recording input. Helps the amplifier reject noise and is part of electrical safety.
  • High-frequency filter: Reduces very fast activity such as muscle. Often 70 Hz for routine EEG.
  • HIPAA: The US law that protects patient health information.
  • Hyperventilation: Deep, steady breathing, usually for 3 minutes, to bring out certain patterns such as 3 Hz spike-and-wave.
  • Hypsarrhythmia: Chaotic, very high-amplitude background in infants with epileptic spasms.
  • Ictal: During a seizure. Interictal means between seizures; postictal means right after one.
  • Impedance: Opposition to current between electrode and skin, in kilohms. A common target is below 5 kΩ and balanced.
  • Inion: The bump at the back of the skull. The back landmark for head measurement.
  • K-complex: A large slow wave with a sharp start in stage N2 sleep, often after a sound.
  • Long-term monitoring: EEG recorded for hours to days, in an EMU or ICU.
  • Low-frequency filter: Reduces very slow activity such as sweat sway. Often 1 Hz for routine EEG.
  • Montage: The set of electrode pairs shown on screen, one pair per channel.
  • Nasion: The dip between the forehead and the nose. The front landmark for head measurement.
  • Notch filter: Removes power-line noise: 60 Hz in North America. Use only when needed, and note it.
  • Periodic discharges: Discharges repeating at fairly regular intervals, described in ACNS critical care terminology.
  • Phase reversal: In a bipolar chain, two neighboring channels deflecting toward or away from each other. The shared electrode is the source.
  • PHI: Protected health information: anything that can identify a patient, including video of the face.
  • Photic driving: The occipital rhythm following the flash rate. A normal response.
  • Photic stimulation: Flashing a strobe at a series of frequencies to look for driving or abnormal responses.
  • Photomyogenic response: Frontal muscle twitches time-locked to the flash. Artifact, not brain activity.
  • Photoparoxysmal response: Epileptiform discharges triggered by the flashing light.
  • Posterior dominant rhythm: The main background rhythm over the occipital regions with the eyes closed. Measured in Hz and described by the technologist.
  • Preauricular point: The dip just in front of the ear. Landmark for the side-to-side measurement.
  • R. EEG T.: Registered Electroencephalographic Technologist, earned by passing ABRET’s EEG exam.
  • Reactivity: A change in the EEG with stimulation, such as the posterior rhythm getting smaller when the eyes open.
  • Referential montage: Each channel compares an electrode with a common reference, such as the ears or an average.
  • Salt bridge: Paste smeared between neighboring electrodes, shorting them so their channel looks nearly flat.
  • SBAR: Situation, Background, Assessment, Recommendation: a structured handoff.
  • Semiology: What a seizure looks like: the movements and behavior during the event.
  • Sensitivity: Microvolts per millimeter of pen deflection. A lower number draws bigger waves. Routine is often 7 µV/mm.
  • Sharp wave: A pointed transient lasting 70 to 200 ms.
  • Sleep spindles: Bursts of about 12 to 14 Hz activity over the central regions in stage N2 sleep.
  • Spike: A pointed transient lasting 20 to under 70 ms that stands out from the background.
  • Spike-and-wave: A spike followed by a slow wave. 3 Hz generalized spike-and-wave is linked with absence seizures.
  • Status epilepticus: A seizure lasting too long or repeated seizures without recovery between them. A medical emergency.
  • Theta activity: 4 to under 8 Hz. Normal in drowsiness and in children; can be abnormal when focal or excessive in an awake adult.